[Read a summary of the overall Minnesota permit, stormwater monitoring, and sector requirements]
Caltha LLP will be conducted seminars on the proposed sector requirements in July & August 2009. Caltha MPCA Industrial Stormwater Permit Requirements Seminars
The proposed permit details requirements for 29 different industrial sectors. The requirements described below are proposed for the Food and Kindred Products Sector (Sector U). Sector U covers a fairly broad range of facility types, including meat products, dairy products, bakeries, beverage products, and many others. These requirements are in addition to permit requirements that apply to all sectors.
Employee Training:
SWPPP training programs must include information on:
1) used oil and spent solvent management;
2) segregation of organic materials, raw materials, and products from contact with stormwater and precipitation; and
3) pest control
[Read more about Minnesota stormwater training]
Inspections:
Inspections must include:
a) waste management units;
b) vents and stacks associated with industrial activities;
c) spoiled product and broken product container holding areas;
d) animal holding pens;
e) staging areas; and
f) air pollution control equipment.
At least two of the monthly inspections must be conducted during runoff events. One of the inspections must be performed during a snow melt runoff event.
Stormwater Pollution Prevention Plan (SWPPP) Content:
The SWPPP must identify:
1) vents and stacks from cooking, drying, and similar operations;
2) dry product vacuum transfer lines;
3) animal holding pens;
4) spoiled product; and broken product container storage areas.
Potential Pollutant Sources:
The SWPPP must describe application and storage of pest control chemicals (e.g., rodenticides, insecticides, fungicides) used on plant grounds.
Stormwater Monitoring Benchmarks:
All facilities are required to conduct visual and chemical (benchmark) monitoring. For benchmark monitoring, the benchmark concentrations or values depend on product type:
Grain Mill Products:
TSS 100 mg/L
Fats and Oils Products:
TSS 100 mg/L
BOD5 25 mg/L
COD 120 mg/L
Ammonia 34.8 mg/L
Total nitrogen None
All Other Food Sectors:
TSS 100 mg/L
BOD 25 mg/L
COD 120 mg/L
Ammonia 34.8 mg/L
Total nitrogen 10 mg/L
Phosphorus 1.0 mg/L
Note: Benchmarks for ammonia and nitrate were derived based on the Aquatic Life Standards for these parameters in Minnesota Rules.
[Read more about use of Aquatic Life Standards to derive stormwater benchmarks]
[Read more about how benchmarks are used under the proposed MPCA industrial permit]
[Read more about what a 100 mg/L benchmark for TSS relates to]